Edge DC 5, the micro data center Designed by Sertronix

Edge DC 5 brings everything a server room needs into one sealed 42U cabinet: precision cooling, protected power, monitoring and access control, for 5 kW of IT equipment.

  • 42Usealed cabinet
  • 600 × 1400mm footprint, 2000 mm high
  • 5 kWIT load
  • A + Btwo power feeds
INSIDE THE ROOM OUTSIDE 12 Cu · 12 FO UPS COOLING READY Heat leaves the building

01

A server room in one cabinet

  • Sealed 42U cabinet600 × 1400 × 2000 mm: room air, dust and humidity stay outside.
  • Built-in precision coolingIn a closed loop, with an outdoor unit: heat leaves the building, no room air conditioning needed.
  • 5 kW of IT loadOn two power feeds, one protected by a UPS.
  • Built-in monitoringTemperature, humidity, smoke, water leak, energy and doors, with remote alerts.
  • Access controlCard, PIN and biometrics on the front and rear doors, with a log of every opening.
  • Emergency ventilationIf cooling stops.
  • All accessories includedEvery free U blanked so cold air goes through your equipment.

02

Your equipment, your network

You bring your servers, storage and network equipment. Edge DC 5 connects to your existing cabling through a 1U panel with 12 copper and 12 fibre ports. You keep your architecture; we provide the environment.

Where it fits

  • Server rooms without suitable cooling, or shared with other uses.
  • Remote sites: branches, plants, warehouses, logistics platforms.
  • Edge IT that must stay on site: production, CCTV, local applications.
  • Adding capacity quickly, without building works.

03

How we proceed

  1. 01Site survey with measurementsFree and with no commitment: for 24 to 48 hours we log your current rack's load, room temperature and humidity, and outdoor temperature.
  2. 02Site checksOutdoor unit position, pipe route, floor, access, power supply.
  3. 03SizingOf load, battery autonomy and options, based on the measurements.
  4. 04Factory build and testBefore delivery, then installation and commissioning on site.
  5. 05MaintenancePreventive and corrective, by our teams in Morocco.

04

Frequently asked questions

How is it different from a standard server rack?

A standard rack depends on the room's cooling and security. Edge DC 5 brings its own cooling, protected power, monitoring and access control.

What do we need on site?

Space for the cabinet, a dedicated power supply and an outdoor position for the cooling unit, on the roof or a wall. The site survey checks each of these.

Why a survey if we already know our load?

Real peaks, room temperature and the outdoor unit's position decide the sizing and the fixed price. The survey is free and commits you to nothing.

How much battery autonomy?

You choose it to fit your needs. Beyond a few tens of minutes we recommend a generator, because the room is no longer cooled during an outage.

Is Edge DC 5 available?

Edge DC 5 is in its launch phase. Contact us for a site survey and a first sizing.

Request your site survey with measurements.

48 hours of measurements, a report and a sizing, with no commitment.

Request a site survey